Leuze it 3820 Скачать руководство пользователя страница 1

Leuze electronic GmbH + Co. KG

In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0

[email protected]  •  www.leuze.com

We

 re

se

rve the

 r

ight to ma

ke

 c

h

an

ges • DS_IT38

20_en_50

1066

70_01.

fm

Hand-held scanner for barcodes

Transmission to ST 2020 base station via 
Bluetooth standard V1.2

Large reading field for the detection of 
codes

Robust trigger button

Built-in decoder

Read-display

RS 232, USB and PS/2 interface

Operating temperature from 0 through 
50°C 
(-10 through 50°C)

9 V

DC

Accessories

TTL-RS 232-cable/PIN 9 IT 4xxx

 

Part No. 501 04586

PS/2-cable for IT 4xxx

 

Part No. 501 03409 

USB-cable for IT 4xxx 

 

Part No. 501 03404

Power supply unit for IT 4x2x 

Part No. 501 03989

IT 3820

:

IT 3820i

:

IP 41

IP 41

IP 54

Dimensioned drawing

Electrical connection

for TTL RS 232 cable / PIN 9

for USB cable 

for PS/2 cable 

9-pin Sub-D

Signal

IT 3820 RJ41

SH

Shield

2

2

TXD

6

3

RXD

5

5

GND

4

7

CTS

9

8

RTS

8

9

5VDC

7

USB type A

Signal

IT 3820 RJ41

1

5VDC

7 + 3

2

Data  -

10

3

Data  +

2

4

GND

4

Mini DIN connector

Mini DIN socket

Signal

IT 3820 RJ41

1

-

PC  Data

6

2

2

NC

3

3

GND

4

4

4

5VDC

7

5

-

PC  Clock

5

6

6

NC

-

1

KB Data

8

-

5

KB  Clock

9

IT 3820/3820i

Hand-held barcode scanner with Bluetooth data transmission

IT 3820/3820i - 06

Specifications and description

en

06

-2

01

4/

07

5

0

1

066

70

-0

1

Содержание it 3820

Страница 1: ...4586 PS 2 cable for IT 4xxx Part No 501 03409 USB cable for IT 4xxx Part No 501 03404 Power supply unit for IT 4x2x Part No 501 03989 IT 3820 IT 3820i IP 41 IP 41 IP 54 Dimensioned drawing Electrical...

Страница 2: ...0 C 60 C Relative air humidity 0 95 non condensing 0 95 non condensing 0 95 non condensing Light source exempt group in acc with EN 62471 Protection class IP 41 IP 54 IP 41 Certifications IEC 60950 1...

Страница 3: ...er A green target line as well as the red illumination should now be visible Now scan a sample label The scanner emits an audible signal to confirm that the label has been read if necessary the data a...

Страница 4: ...t in trigger button Configuration for the Leuze standard protocol To set the Leuze standard protocol you must first reset the scanner to factory settings and then individually define each of the trans...

Страница 5: ...nd the other end into a free power socket 5 4 Switch the PC back on 5 Scan the adjacent barcode The IT 3820 is set to the following transmission parameters RS 232 transmission with 115 200 baud 8 data...

Страница 6: ...ble KB 021 Z to the MA 41 acc to the above pin assignments 2 Connect the interface cable to cable KB 021 Z Connect the interface cable and the power supply unit to the base station see Connecting the...

Страница 7: ...in assignments 2 Connect the interface cable to cable KB 021 Z Connect the interface cable and the power supply unit to the base station see Connecting the IT 3820 to the serial PC interface 3 Scan th...

Страница 8: ...on ST 2020 1x 501 03 989 Power supply unit ST 2020 1x 501 03 409 PS 2 cable Procedure 1 Switch off the PC 2 Disconnect the keyboard 3 Connect the cable for the ST 2020 base sta tion between the keyboa...

Страница 9: ...n be processed further in all standard programs required parts 1x 501 06 242 IT 3820 SR 0C0BE 1x 501 03 990 Base station ST 2020 1x 501 03 989 Power supply unit ST 2020 1x 501 03 404 USB cable Procedu...

Страница 10: ...20 SR 0C0BE 1x 501 03 990 Base station ST 2020 1x 501 03 989 Power supply unit ST 2020 1x 501 03 404 USB cable Procedure 1 Connect the cable for the ST 2020 base station to a free USB port 2 The scann...

Отзывы: