Mounting
Leuze electronic GmbH + Co. KG
DCR 258i
48
6.3
Replace housing hood
In individual cases, you can exchange the housing hood of the code reader, e.g., if the protective screen is
scratched or if changed operating conditions necessitate a housing hood with polarization filter. For order-
ing information, see chapter 16.3 "Optical accessories".
NOTICE
Replacement of housing hood not permitted with stainless steel housing!
Ä
On devices with stainless steel housing, it is not permitted to replace the housing hood.
NOTICE
Only replace the housing hood while the device is in a de-energized state!
Only replace the housing hood if no voltage is being applied to the device.
Ä
Disconnect the device from the voltage supply before replacing the device hood.
NOTICE
Check the seal before mounting!
Ä
Check the seal on the base of the code reader housing for cleanliness before mounting the
new housing hood.
NOTICE
Clean the new housing hood before mounting!
Ä
Clean the new housing hood with a soft cloth before mounting.
Ä
Loosen the four fastening screws of the housing hood.
Ä
First tip the housing hood downward and away from the housing base.
Ä
Then lift the housing hood up and off of the housing base.
Ä
Then mount the new housing hood in the reverse order. The tightening torque of the fastening screws
is 0.25 Nm.
1
2
2
1
Fastening screws
2
Housing hood
Fig. 6.22:
Replace housing hood