![Leuze DCR 258i Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/leuze/dcr-258i/dcr-258i_original-operating-instructions_1883777016.webp)
Device description
Leuze electronic GmbH + Co. KG
DCR 258i
16
NOTICE
NET indicator only for Ethernet communication!
The NET indicator refers only to the Ethernet communication, not to the RS 232/RS 422.
LINK LED
Tab. 3.3:
LINK indicators
Color
State
Description
Green
ON (continuous light)
Ethernet connected (LINK)
Yellow
Flashing
Data communication (ACT)
3.4.2
Bar graph display
Function selection
NOTICE
Devices with stainless steel housing do not have any control buttons.
Devices with stainless steel housing do not have a bar graph indicator.
The following functions are selected and displayed via the bar graph display (see chapter 8.5 "Activating
device functions"):
•
TRIG
: Trigger function for activating a read process
•
AUTO
: Auto setup function for determining the optimum read setting
•
ADJ
: Adjustment function for aligning the device
•
TEACH
: Teach function for teaching a reference code
The individual functions are selected and activated with the control buttons.
• Select function with the navigation button
: The function LED flashes.
• Activate function with the enter button
: The function LED illuminates continuously.
NOTICE
A preselected function (flashing LED) does not yet have any influence on the functionality. If no
button is pressed for a longer period of time, flashing of the LED is ended automatically by the
device.
NOTICE
If you activate the
TRIG
,
AUTO
,
ADJ
or
TEACH
function via the control buttons, the device ac-
cepts no commands via the process interface. Process mode is thereby interrupted.
NOTICE
On devices with stainless steel housing, it is not possible to select functions using the control
buttons.