More conveniently, you can configure the light curtains of the CSL 710 series us-
ing the IO-Link interface. We recommend our IO-Link master from the MD series
in this regard.
Configuration is performed using the
Sensor Studio configuration software.
Download software
Ä
Call up the Leuze home page: www.leuze.com
Ä
Enter the type designation or part number of the device as the search term.
Ä
The configuration software can be found on the product page for the device
under the
Downloads tab.
In order to have the IODD profiles available, you should also download the IODD
files, as well as the
IO-Link Device Collection.
More information can be found in the operating instructions.
Technical data
See chapter "Technical data" of the operating instructions
Technical drawings
2
CSL 710 with axial connector outlet
All dimensions in mm
A
Beam spacing
B
Measurement field length
C
PWR IN/Digital IO and IO-Link interface
D
Connection to transmitter
E
Connection to receiver
F
M6 thread
G
Fastening groove
L
Profile length
R
Receiver
T
Transmitter
Y
Devices with beam spacing 5 mm; Y = 2.5 mm
Devices with beam spacing 10, 20, 40 mm; Y = 5 mm
Electrical connection
The light curtains of the CSL 710 series operate the following interface:
– IO-Link
The transmitters have an M12 connector.
The receivers have two M12 connectors.