Functions
Leuze electronic
CML 730-PS
27
4.7
Power-Up Teach
After applying operating voltage, the “Power-Up Teach” function performs a teach event when the device
is ready for operation.
• If the Power-Up teach is successful, the new teach values are adopted if they are different from the
previously stored teach values.
• If the Power-Up teach is not successful (e.g. object in the light path), the previously saved teach val
-
ues are used.
4.8
Smoothing
With the smoothing function, interrupted beams are then only taken into account in the evaluation if the set
minimum number of adjacent beams is reached at the same time.
Smoothing can be used, e.g., to suppress interference caused by spot soiling of the lens cover.
Smoothing “1” means that every interrupted beam is evaluated.
If the
Auto blanking
function is activated via the receiver control panel, up to four blanking areas
are automatically permitted.
Auto blanking cannot be used to detect transparent objects.
Deactivated beams are lost if the beam mode is changed while auto blanking is active.
NOTICE
Deactivate auto blanking in process mode!
Deactivate auto blanking in process mode.
Activate auto blanking only during commissioning of the device to suppress distracting objects.
NOTICE
Deactivate auto blanking during Power-Up Teach!
Deactivate auto blanking if “Power-Up Teach” is activated (see chapter 4.7).
NOTICE
Resetting all blanking areas!
To deactivate blanking areas, leave auto blanking active with at least the same number of blanking
areas.
Perform a new teach in a free measurement field.
To deactivate blanking with the
Sensor Studio
configuration software, configure the number of blank
-
ing areas as zero and, at the same time, deactivate each area.
Perform a new teach.
NOTICE
Deactivate auto blanking during Power-Up Teach!
Deactivate auto blanking if “Power-Up Teach” is activated.
NOTICE
No objects in the light path!
During “Power-Up Teach”, ensure that no beams are partially covered by an object.