Electrical connection
Leuze electronic GmbH + Co. KG
BPS 8
44
Figure 7.9: Electrical connection MA 8-01/MA 8-02
7.4.3 BCL/BPS socket – connecting the BPS 8 to the MA 8
-
01/MA 8
-
02
Figure 7.10: MA 8-01/MA 8-02 – Pin assignment BCL/BPS socket
CAUTION
Degree of protection IP 67!
Degree of protection IP 67 is achieved only if the connectors and caps are screwed into place!
NOTE
The switching input/switching output are programmed via the parameters in the BPS Configu
-
ration Tool configuration software. For further information, see see chapter 8.2, see page 46
et seq.
CAUTION
Connecting a sensor with standard M12 connectors!
If you use a sensor with a standard M 12 connector, please note the following:
Use only sensors on which the switching output does not lie on pin 2 or sensor cables on
which pin 2 is not assigned. Otherwise, the switching output is not protected against feed
-
back on the switching input. If the inverted sensor output lies on pin 2, erroneous behavior
of the switching output will result.
Switching input
Switching output
BCL/BPS (5-pin socket, A-coded)
Pin
Name
Comment
1
VIN
Supply voltage for BPS 8 aprox. +5.2VDC
2
TXD
RS 232 transmission line
3
GND
Supply voltage: 0VDC
4
RXD
RS 232 receiving line
5
SWIN/
SWOUT
Programmable switching input/output of the BPS 8
Thread
FE
Functional earth (housing)
1
2
3
4
5
RXD
VIN
GND
SWIN/SWOUT
TXD
BCL / BPS
M12 socket
(A-coded)