8.1.7.10 Module 10: Measurement value acquisition
Description
With this module, a working range on the barcode tape can be defined. The BPS 34 outputs
position values within these minimum and maximum limits. Outside of these limits, a position
value of zero is output.
Parameter
Notice!
The signal output can be used to indicate that the measured value is outside of the meas-
urement range. To enable this function, the "outside measurement range" or "inside meas-
urement range" parameter must be activated in module 8.
Hex coding of module 10 "Measurement value acquisition"
The value listed in the table shows the hex coding of the default settings.
Input data
none
Output data
none
Parameter
Description
Rel.
addr.
Data
type
Value range
Default
Unit
CR to
module
Max.
measurement
length in [mm]
Maximum permitted meas-
urement length
0
unsign
32
0 … 2’147’483’647
10’000’000
mm
8d
Min.
measurement
length in [mm]
Minimum permitted meas-
urement length
4
unsign
32
0 … 2’147’483’647
0
mm
8d
Parameter length: 8 byte
a
b
Internal ad
dress
of module 10
Max. measurement length
ad
dress 0
Min. measurement length
ad
dress 4
04
00 98 96 80
00 00 00 00