Starting up the device – Basic configuration
Leuze electronic GmbH + Co. KG
BPS 307i
54
8.5
Setting tape selection via the webConfig tool
Ä
In the webConfig tool (
CONFIGURATION
>
MEASUREMENT DATA
>
Bar code tape
), set the
Tape
selection
parameter according to the used bar code tape grid (see chapter 9.3.4 "CONFIGURATION
• 30 mm grid
• 40 mm grid
8.6
Configuration via the switches of the connection hood
The following settings can be configured via the operational controls of connection hoods MS 307 and
MK 307:
• Resolution of the position value
• Data encoding of the measurement values:
Gray
or
binary
• Speed monitoring via switching output (SWIO1)
NOTICE
The settings made via the operational controls of the connection hood can alternatively be con-
figured via the webConfig tool; see chapter 9.3.4 "CONFIGURATION function". To do this, ro-
tary switch S2 must be set to switch position
0
.
If rotary switch S2 is set to switch position
0
, slide switch S1 is not evaluated.
1
2
1
Slide switch S1
Factory setting: Gray encoding
2
Hexadecimal rotary switch S2
Factory setting:
0
, i.e., configuration via the webConfig tool
Fig. 8.2:
Operational controls of connection hood MS 307