![Leuze BCL604i Скачать руководство пользователя страница 92](http://html1.mh-extra.com/html/leuze/bcl604i/bcl604i_operating-instructions-manual_1883769092.webp)
Starting up the device - Configuration
Leuze electronic
BCL 604i
92
Input data length:
2 bytes
Output data
Table 10.53:
Output data for module 74 Input/output status and control
Output data length:
2 bytes
10.13 Data output
10.13.1Module 80 – Sorting
Description
Module to support the sorting of the output data.
Switching output 3
Comparison state tog
-
gle bit
(Event Counter)
If “SWOUT switches several times” was con
-
figured as comparison mode, this bit is toggled
each time the event counter is exceeded.
The bit is reset to the init. value by resetting
the event counter.
1.5
Bit
0 -> 1: Event counter
exceeded
1 -> 0: Event counter
exceeded again
0
-
Comparison state
switching output 4
(Event Counter)
Indicates whether the event counter has
exceeded the set comparative value.
The bit is reset to the init. value by resetting
the event counter.
1.6
Bit
0: Not exceeded
1: Exceeded
0
-
Switching output 4
Comparison state tog
-
gle bit
(Event Counter)
If “SWOUT switches several times” was con
-
figured as comparison mode, this bit is toggled
each time the event counter is exceeded.
The bit is reset to the init. value by resetting
the event counter.
1.7
Bit
0 -> 1: Event counter
exceeded
1 -> 0: Event counter
exceeded again
0
-
Parameter
Description
Addr.
Data type
Value range
Init value Unit
Output data
Description
Addr.
Data type
Value range
Init value Unit
Switching output 1
Sets the state of switching output 1
0.0
Bit
0: Switching output 0
1: Switching output 1
0
-
Switching output 2
Sets the state of switching output 2
0.1
Bit
0: Switching output 0
1: Switching output 1
0
-
Switching output 3
Sets the state of switching output 3
0.2
Bit
0: Switching output 0
1: Switching output 1
0
-
Switching output 4
Sets the state of switching output 4
0.3
Bit
0: Switching output 0
1: Switching output 1
0
-
Reset Event Counter
Switching output 1
Sets the event counter of the activation func
-
tion [AF] for switching output 1 back to zero.
0.4
Bit
0 -> 1: Perform reset
1 -> 0: No function
0
-
Reset Event Counter
Switching output 2
Sets the event counter of the activation func
-
tion [AF] for switching output 2 back to zero.
0.5
Bit
0 -> 1: Perform reset
1 -> 0: No function
0
-
Reset Event Counter
Switching output 3
Sets the event counter of the activation func
-
tion [AF] for switching output 3 back to zero.
0.6
Bit
0 -> 1: Perform reset
1 -> 0: No function
0
-
Reset Event Counter
Switching output 4
Sets the event counter of the activation func
-
tion [AF] for switching output 4 back to zero.
0.7
Bit
0 -> 1: Perform reset
1 -> 0: No function
0
-
Reserved
1
Byte