PROFIBUS
Leuze electronic
BCL 34
87
TNT
35/7-2
4
V
8.3.36
RS 232
Module 50
If this module is not configured, the decoding result is also output in the ASCII framing
protocol on the serial interface (RS 232). The baud rate, data format, and prefix and postfix
characters can be configured. In the standard configuration, the Leuze framing protocol is
used. Its structure is <STX><Data><CR><LF> with data format 8 data bits, no parity and
1 stop bit (8N1) and a transmission speed of 9600 Baud.
Parameters
Input Data
none
Output Data
none
Parameter
Description
Rel.
addr.
Data type
Value Range
Default
Unit
CR to
module
Baud rate
Transmission speed of the serial interface.
7:
9600 baud
8:
19200 baud
9:
38400 baud
10:
57600 baud
11:
115200 baud
7
–
Data format
Data format of the serial interface.
Consists of number of data bits, parity, and
number of stop bits.
The code 8,n,1, for example, means 8 data
bits, no parity and 1 stop bit.
The parity can be n=none, e=even, o=odd.
1:
7,n,2
2:
7,e,1
3:
7,e,2
4:
7,o,1
5:
7,o,2
6:
8, n, 1
7:
8,n,2
8:
8,e,1
9:
8,e,2
10:
8,o,1
11:
8,o,2
6
–
Prefix
character 1
First framing character that precedes the data
part. ASCII character as decimal number, see
ASCII table.
0 … 127
2 (STX)
–
Prefix
character 2
Second framing character that precedes the
data part. ASCII character as decimal number,
see ASCII table.
0 … 127
0
(deacti-
vated)
–
Prefix
character 3
Third framing character that precedes the data
part. ASCII character as decimal number, see
ASCII table.
0 … 127
0
(deacti-
vated)
–
Postfix
character 1
First framing character that is appended to the
data part. ASCII character as decimal number,
see ASCII table.
0 … 127
13 (CR)
–
Postfix
character 2
Second framing character that is appended to
the data part. ASCII character as decimal
number, see ASCII table.
0 … 127
10 (LF)
–
Postfix
character 3
Third framing character that is appended to
the data part. ASCII character as decimal
number, see ASCII table.
0 … 127
0
(deacti-
vated)
–
Parameter length: 8 bytes
a
b
c
d
e
f
g
h
Содержание BCL34
Страница 1: ...BCL34 Barcode reader GB 05 10 08 50038851 T E C H N I C A L D E S C R I P T I O N...
Страница 98: ...Appendix 96 BCL 34 Leuze electronic 12 Appendix 12 1 EU Declaration of Conformity...
Страница 102: ...Index 100 BCL 34 Leuze electronic V Vibration 18 W Warm up time 18 Warning notices 8 Weight 17...