Starting up the device – Configuration
Leuze electronic GmbH + Co. KG
BCL 8
52
Figure 10.1: Bar code label "Service"
While the laser switches on for approx. 1s after power-up, the "Service" label is to be held up in front of
the bar code reader at a suitable read distance.
When the device is in "Service" mode, the status LED flashes orange.
10.4.2 Parameter sets
The configuration settings are stored in the memory of the bar code reader in parameter sets.
• Factory default parameter set
• Current parameter set
Factory default parameter set
This parameter set contains the factory-set default settings for all parameters of the bar code reader. It is
permanently stored in the FLASH ROM of the bar code reader.
The parameter set with the default settings is loaded into the memory of the bar code reader:
• The first time the device is commissioned after delivery
• With the
Sensor Studio
configuration software via the [Factory Default] button in the DIAGNOSIS
menu.
• After the online command PC20 (see chapter 11.1.3 "’Online’ commands for parameter set opera
• If the checksums of the current parameter set are invalid
Current parameter set
In this parameter set, the current settings for all device parameters are stored. When the bar code reader
is in operation, the current parameter set is stored in the EEPROM of the bar code reader.
The current parameter set is loaded into the main memory of the bar code reader with the Copy parameter
set parameter set command (see chapter 11.1.3 "’Online’ commands for parameter set operations").
You can save the current parameter set as follows:
• Copying a valid parameter set from the host computer into the bar code reader
• Off-line configuration using the
Sensor Studio
configuration software and then subsequently loading
to the bar code reader
NOTE
To load the configuration into the bar code reader, select online mode.