9.5.7 Switch tab
Figure 9.14:
Switching output
tab
Pulse duration
If the value is higher than "0": duration of the activation, regardless
of how long the trigger signal has been present.
Switch-off delay
After the end of the trigger signal, the pulse is extended internally
by this time period.
Function
(Control)
Event that is started when the switching input is activated.
NOTE
If switch-off delay is activated, the
pulse duration
parameter should be "0".
NOTE
Type and source of the danger
The configuration options are identical for both switching outputs SWOUT 1 and SWOUT 2.
Activation
Select the desired event which is to initiate the switching of the
switching output here.
Multiple events can also be simultaneously activated.
Deactivation
Shown here is the event which results in the switching output
being reset if the set pulse duration has not yet expired.
Multiple events can also be simultaneously activated.
Inverted
Here, the input level can be inverted
Pulse duration
Duration of the switching output pulse.
Pulse delay time