Display elements and display
Leuze electronic GmbH + Co. KG
BCL 358
i
68
8
Display elements and display
The BCL 358
i
is available optionally with display, 2 control buttons and LEDs or with only 2 LEDs as
display elements.
8.1
BCL 358
i
LED indicators
Figure 8.1: BCL 358
i
- LED indicators
2 multicolor LEDs are used as the primary display instrument.
LED functions:
PWR LED
Off
Device OFF
- No supply voltage
Green, flashing
Device ok, initialization phase
- No bar code reading possible
- Voltage connected
- Self test runs for 0.25s after power up
- Initialization running
Green, continuous light
Device ok
- Bar code reading possible
- Self test successfully finished
- Device monitoring active
Green, briefly off - on
Good read, successful reading
- Bar code(s) successfully read
Green, briefly off -
briefly red - on
No read, reading not successful
- Bar code(s) not read
Orange, continuous light
Service mode
- Bar code reading possible
- Configuration via the USB service interface
- No data on the host interface
Red, flashing
Warning set
- Bar code reading possible
- Self test runs for 0.25s after power up
- Temporary operating fault
2 LEDs