Electrical connection
Leuze electronic GmbH + Co. KG
BCL 358
i
59
7.2
BCL 358
i
electrical connection
For the electrical connection of the BCL 358
i
, 2 connection variants are available.
The voltage supply (18 … 30VDC) is connected acc. to the connection type selected.
2 freely programmable switching inputs/outputs for individual adaptation to the respective application are
also available here. Detailed information on this topic can be found in Chapter 7.3.1.
7.2.1 MS 358 connector hood with 3 integrated M12 connectors
The MS 358 connector hood features three M12 connector plugs and a Mini-B type USB socket as a
service interface. Parameter memory is integrated into the MS 358 which temporarily stores the settings
of the BCL 358
i
in the case of replacement and transmits them to a new device.
Figure 7.2: BCL 358
i
- MS 358 connection hood with M12 connectors
7.2.2 MK 358 terminal hood with spring-cage terminals
The MK 358 terminal hood makes it possible to connect the BCL 358
i
directly and without additional
connectors. The MK 358 features three cable lead-throughs in which the shielding connection for the inter
-
face cable is also located. The BCL 358
i
is also to be configured when the MK 358 is in a closed state via
a Mini-B type USB socket functioning as the service interface. Parameter memory is integrated into the
MK 358 which temporarily stores the settings of the BCL 358
i
in the case of replacement and transmits
them to a new device.
NOTE
The shielding connection is done via the M12 connector housing.
NOTE
The integrated parameter memory for the simple replacement of the BCL 358
i
is located in the
MS 358. In the integrated parameter memory, both the settings and the network address are
saved and transmitted to a new device.
NOTE
In the case of Ethernet linear topology, the network is interrupted when the BCL 301
i
is removed
from the MS 358.
NOTE
Dimensioned drawing on see chapter 5.3.5 "Dimensioned drawings of MS 3xx / MK 3xx connec
PWR / SW IN/OUT
SWIO_2
SWIO_1
3
2
1
4
5
GNDIN
VIN
FE
SERVICE
2
1 3 5
4
GND
D+
D-
VB
ID
BUS OUT
HOST / BUS IN
TD+ 1
2
3
4
RD+
RD-
TD-
TD+ 1
2
3
4
RD+
RD-
TD-
Mini-B USB socket
(behind protective cap)
M12 connector
(A-coded)
M12 socket
(D-coded)
Ethernet 0
M12 socket
(D-coded)
Ethernet 1
Connector hood
MS 358
Ethernet 1 LED
(split, two-colored):
ACT1 / LINK1
Ethernet 0 LED
(split, two-colored):
ACT0 / LINK0