Fast commissioning / operating principle
Leuze electronic GmbH + Co. KG
BCL 358
i
13
MS 358 connector hood with 2 integrated M12 connectors
Figure 3.1: BCL 358
i
- MS 358 connection hood with M12 connectors
MK 358 terminal hood with spring-cage terminals
Figure 3.2: BCL 358
i
- MK 358 terminal hood with spring-cage terminals
NOTE
The shielding connection is done via the M12 connector housing.
NOTE
The integrated parameter memory for the simple replacement of the BCL 358
i
is located in the
MS 358. In the integrated parameter memory, both the settings and the network address are
saved and transmitted to a new device.
NOTE
In the case of Ethernet linear topology, the network is interrupted when the BCL 301
i
is removed
from the MS 358.
PWR / SW IN/OUT
SWIO_2
SWIO_1
3
2
1
4
5
GNDIN
VIN
FE
SERVICE
2
1 3 5
4
GND
D+
D-
VB
ID
BUS OUT
HOST / BUS IN
TD+ 1
2
3
4
RD+
RD-
TD-
TD+ 1
2
3
4
RD+
RD-
TD-
Mini-B USB socket
(behind protective cap)
M12 connector
(A-coded)
M12 socket
(D-coded)
Ethernet 0
M12 socket
(D-coded)
Ethernet 1
Connector hood
MS 358
Ethernet 1 LED
(split, two-colored):
ACT1 / LINK1
Ethernet 0 LED
(split, two-colored):
ACT0 / LINK0
Terminal hood
MK 358
SERVICE
2
1 3 5
4
GND
D+
D-
VB
ID
Mini-B USB socket
(behind protective
cap)
Te
rmi
na
l b
loc
k
PWR
/ SW
IN
/OUT
Te
rmi
na
l b
loc
k
HOS
T /
BUS I
N
(Ethe
rnet 0
)
Terminal designation
MK 358
Te
rmi
na
l b
loc
k
BUS
OUT
(Ethe
rnet 1
)
Ethernet 1 LED
(split, two-colored):
ACT1 / LINK1
Ethernet 0 LED
(split, two-colored):
ACT0 / LINK0
LEDs