Commissioning and configuration
Leuze electronic GmbH + Co. KG
BCL 300
i
\ BCL 301
i
95
10.4 Transmitting configuration data
Instead of going through the tedious task of configuring every parameter of the BCL 300
i
\ BCL 301
i
indi
-
vidually, you can also conveniently transfer configuration data.
Configuration data can be transferred between two bar code readers BCL 300
i
\ BCL 301
i
as follows
• Storage in a file and transfer using the webConfig tool
10.4.1 Via the webConfig tool
With the webConfig tool, you can store entire configurations of the BCL 300
i
\ BCL 301
i
on data carriers
and transfer them from these to the BCL 300
i
\ BCL 301
i
.
This storage of configuration data is especially useful if you want to store basic configurations which will
require only minor changes.
In the webConfig tool, you store the configuration data via the buttons in the upper part of the middle
window of all submenus of the
Configuration
main menu.
Figure 10.1: Storing configuration data in the webConfig tool
10.4.2 Replacing a defective BCL 300
i
\ BCL 301
i
The MS 300/MS 301 hoods with integrated connectors and the MK 300/MK 301 terminal hoods feature an
integrated parameter memory in which the configuration data is saved as a backup. If a defective BCL 300
i
\ BCL 301
i
has to be replaced, proceed as follows:
Disconnect the defective BCL 300
i
\ BCL 301
i
from the voltage supply.
Dismount the defective BCL 300
i
\ BCL 301
i
and disconnect it from the hoods with integrated connec
-
tors/terminal hoods.
Connect the new BCL 300
i
\ BCL 301
i
to the connection hood and remount the unit.
Recommission the new BCL 300
i
\ BCL 301
i
(reconnect the voltage supply).
The configuration is now imported from the external parameter memory of the connection hood and the
BCL 300
i
\ BCL 301
i
is immediately operational without any further configuration.