Example configurations
Leuze electronic GmbH + Co. KG
CML 730i
171
Example: Deactivation/resetting of auto blanking
15.5 Example configuration – smoothing
15.5.1 Smoothing configuration (general)
Make the following settings for smoothing.
Example: Smoothing of four interrupted beams
Example: Inverted smoothing of four interrupted beams
15.5.2 Configuration of smoothing via IO-Link interface
Assign the desired value for smoothing.
Example: Smoothing of four interrupted beams
Example: Inverted smoothing of four interrupted beams
15.5.3 Configuration of smoothing via CANopen interface
Assign the desired value for smoothing.
Example: Smoothing of four interrupted beams
Example: Inverted smoothing of four interrupted beams
Blanking area configuration
(group 8)
Parameter
0x4C configuration of blanking
areas
Write access:
01 10 00 4C 00 0D 1A 02 01 00 00 01 00 01 00 00 00 01 00 01
00 00 00 01 00 01 00 00 00 01 00 01 00 B2 52
Response to write access:
01 10 00 4C 00 0D C0 1B
Rx command
(group 1)
Parameter
0x84 Rx command (teach)
Write access:
01 10 00 84 00 02 04 03 00 00 00 FA 78
Response to write access:
01 10 00 84 00 02 01 E1
Blanking area configuration
(group 8)
Parameter
0x4C configuration of blanking
areas
Write access:
01 10 00 4C 00 0D 1A 00 01 00 00 01 00 01 00 00 00 01 00 01
00 00 00 01 00 01 00 00 00 01 00 01 00 41 ED
Response to write access:
01 10 00 4C 00 0D C0 1B
Command
(group 1)
Parameter
0x84 command (teach)
Write access:
01 10 00 84 00 02 04 03 00 00 00 FA 78
Response to write access:
01 10 00 84 00 02 01 E1
Smoothing settings
Parameter
Smoothing -– less than i interrupted
beams are ignored
:
= 4
Beams are taken into account in the evaluation once
there are four or more interrupted beams
Smoothing settings
Parameter
Inverted smoothing - less than i free
beams are ignored
:
= 4
Beams are taken into account in the evaluation once
there are four or more free beams
If the set configuration of the light curtain is running stably in your application and the measure
-
ment field resolution can be reduced, e.g. in the case of objects to be detected which are consi
-
derably larger than 10 mm, it is recommended to set
Smoothing
and
Inverted smoothing
to a
value > 1.
General configuration
(group 4)
Index 71, bit offset 8:
= 4
Beams are taken into account in the evaluation once there are four or more
interrupted beams
General configuration
(group 4)
Index 71, bit offset 0:
= 4
Beams are taken into account in the evaluation once there are four or more
free beams
General configuration
(module 3)
Index 2100 sub 03:
= 4
Beams are taken into account in the evaluation once there are four or more
interrupted beams