Starting up the device - PROFINET interface
Leuze electronic GmbH + Co. KG
CML 730i
132
13.4.8 Last not interrupted beam (module 04)
The module allows evaluation of the CML 700i information regarding the last not interrupted beam (LNIB).
• Module ID: 1004
• Submodule ID: 1
13.4.9 Total of interrupted beams (module 05)
The module allows evaluation of the CML 700i information regarding the total of interrupted beams (TIB).
• Module ID: 1005
• Submodule ID: 1
13.4.10 Total of not interrupted beams (module 06)
The module allows evaluation of the CML 700i information regarding the total of not interrupted beams
(TNIB).
• Module ID: 1006
• Submodule ID: 1
13.4.11 Beam area 16 to 1 (module 07)
The module allows evaluation of the CML 700i status information regarding beam area 16 to 1.
• Module ID: 1007
• Submodule ID: 1
13.4.12 Beam area 32 to 17 (module 08)
The module allows evaluation of the CML 700i status information regarding beam area 32 to 17.
• Module ID: 1008
• Submodule ID: 1
Input data
Rel.
address
Data type
Value range
Default Explanation
Beam number
0
USIGN 16
0 … 1774
0
Number of the last not interrupted beam
Input data length: 2 byte consistently
Input data
Rel.
address
Data type
Value range
Default Explanation
Number of beams
0
USIGN 16
0 … 1774
0
Number of interrupted beams
Input data length: 2 byte consistently
Input data
Rel.
address
Data type
Value range
Default Explanation
Number of beams
0
USIGN 16
0 … 1774
0
Total of not interrupted beams
Input data length: 2 byte consistently
Input data
Rel.
address
Data type
Value range
Default Explanation
Status
0
USIGN 16
0 … 65535
0
Status of beam areas 16 to 1
0: Beam area logical LOW
1: Beam area logical HIGH; switching condition ful
-
filled
Input data length: 2 byte consistently