Leuze webConfig tool
Leuze electronic GmbH + Co. KG
BCL 308
i
80
Alternatively, you can start the webConfig tool by starting the browser installed on your PC and entering
the following IP address: 192.168.61.100
This is the default Leuze service address for communication with bar code readers of the BCL 300
i
and
BCL 500
i
series.
In both cases, the following start page appears on your PC.
Figure 9.2: The start page of the webConfig tool
The individual parameters are – where useful – graphically displayed in order to better illustrate the
meaning of the what are often perceived as abstract parameters.
The result is an easy-to-use and practically-oriented user interface!
9.4
Short description of the webConfig tool
The webConfig tool has 5 main menus:
•
Process
with read information of the host interface of the connected BCL 308
i
.
•
Alignment
for manually starting read processes and for aligning the bar code reader. The results of the read
processes are displayed immediately. As a result, this menu item can be used to determine the opti
-
mum installation location.
•
Configuration
for adjusting decoding, for data formatting and output, switching inputs/outputs, communication
parameters and interfaces, etc. …
•
Diagnostics
for event logging of warnings and errors
•
Maintenance
for updating the firmware.
The user interface of the webConfig tool is largely self-explanatory.
NOTE
The webConfig tool is completely contained in the firmware of the BCL 308
i
. Depending on firm
-
ware version, the start page may vary from that shown above.