![Leuze 50116368 Скачать руководство пользователя страница 78](http://html1.mh-extra.com/html/leuze/50116368/50116368_original-operating-instructions_1883758078.webp)
Display elements and display
Leuze electronic GmbH + Co. KG
BCL 308
i
76
8.3
BCL 308
i
display
Figure 8.3: BCL 308
i
- Display
The optional display of the BCL 308
i
has the following features:
• Monochromatic with background lighting (blue/white)
• Double line, 128 x 32 pixels
• Display language: English
The display is only used as a display element. Two buttons can control which values are displayed. In
doing so, the upper line displays the selected function and the lower line displays the result.
The background lighting is activated by the push of any button and automatically deactivated after a
defined point in time:
Display functions
The following functions can be displayed and activated:
•
Reading result
= result of reading process
•
Decodequality
= quality of decoding process
•
BCL Info
= device status/error code
•
I/O Status
= status of the inputs/outputs
•
BCL Address
= IP address of the BCL 308
i
•
Adjustmode
= alignment mode
•
Version
= software and hardware version
After the voltage is switched off/on, the
reading result
is always displayed.
The display is controlled via the two control buttons:
ENTER
Activation/deactivation of the display change function
Down
Scroll through functions (downwards)
Example:
Representation of the
BUS status
on the display:
1. Press button : Display flashes
2. Press button : Display changes from read result to decoding quality
3. Press button : Display changes from decoding quality to device status
4. Press button : Display changes from device status to BUS status
5. Press button : Bus status displayed, display stops flashing.
Description of the display functions
NOTE
The function of the LEDs is identical for the devices with and without display.
Control buttons
Display
2 LEDs