11.1.4 Online commands for the parameter set operations
Copying parameter set
NOTE
You can obtain detailed information on the parameter set of the bar code reader from Leuze on
request.
Command
’PC’
Description
This command can only be used to copy parameter sets in their entirety. This can be
used to replicate the three parameter sets default, permanent and operating parameters
on the basis of one another. In addition, this command can also be used to restore the
factory settings.
Parameter
’PC<Source type><Target type>’
<Source type> Parameter data set that is to be copied, unit [dimensionless]
'0'
Parameter data set in permanent memory
'2'
Default or factory parameter set
'3'
Operating parameter data set in volatile memory
<Target type> Parameter set into which the data is to be copied, unit [dimensionless]
'0'
Parameter data set in permanent memory
'3'
Operating parameter data set in volatile memory
Permissible combinations here include:
'03'
Copying the data set from the permanent memory to the operating parameter
data set
'30'
Copying the operating parameter data set to the permanent parameter set
memory
'20'
Copying the default parameters to the permanent memory and to the main
memory
Acknowledg
-
ment
’PS=<aa>’
<aa>
Status acknowledgment, unit [dimensionless]
’00’
Ok
’01’
Syntax error
’02’
Impermissible command length
’03’
Reserved
’04’
Reserved
’05’
Reserved
’06’
Impermissible combination, source type - target type