Description ODSL 30
Leuze electronic GmbH + Co. KG
ODSL 30
35
Serial COM Menu
COM Function sel
ASCII Distance
COM Function sel
ASCII Distance
Serial transmission, output in ASCII, 5 bytes, res
-
olut. 1mm
X
COM Function sel
ASCII Dist. .1mm
Serial transmission, output in ASCII, 6 bytes, res
-
olut. 0.1mm
COM Function sel
Distance 14Bit
Serial transmission, 2 bytes, 15m meas. range,
res. 1mm
COM Function sel
Distance 16Bit
Serial transmission, 3 bytes, 30m meas. range,
res. 1mm
COM Function sel
Distance 20Bit
Serial transmission, 4 bytes, 30m meas. range,
res. 0.1mm
COM Function sel
Remote Control
Remote control activated via
bus commands
COM Function sel
switched OFF
Serial data transmission deactivated
Node Address
Value: 000
Node Address
act Value:
000
Node address 0 … 14
0
Baudrate COM
Baudrate
9600
Baudrate COM
Baudrate
9600
Baud rate 9600 bit/s
X
Baudrate COM
Baudrate
19200
Baud rate 19200 bit/s
Baudrate COM
Baudrate
28800
Baud rate 28800 bit/s
Baudrate COM
Baudrate
38400
Baud rate 38400 bit/s
Baudrate COM
Baudrate
57600
Baud rate 57600 bit/s
Baudrate COM
Baudrate
115200
Baud rate 115200 bit/s
Baudrate COM
Baudrate
600
Baud rate 600 bit/s
Baudrate COM
Baudrate
1200
Baud rate 1200 bit/s
Baudrate COM
Baudrate
2400
Baud rate 2400 bit/s
Baudrate COM
Baudrate
4800
Baud rate 4800 bit/s
Stop bits COM
1
Stop bits COM
1
Number of stop bits: 1
X
Stop bits COM
2
Number of stop bits: 2
Return
Return to level 1
Service Menu
Password Check
inactive
Password Check
inactive
Password for menu access not active
X
Password Check
activated
Menu access password active,
password: 165 (n. changeable)
ODSL30Serial No.
Val:
99999
Display of serial number, no changes possible
SW V01.20 YYMMDD
Val:
31024
Display of software version, no changes possible
Parameter YYMMDD
Val:
31024
Display of parameter version, no changes possi
-
ble
Interface type
RS485 interface
Display of the interface type, no changes possible
Return
Return to level 1
Exit from Menu
Return to measure mode
Level 1
Level 2
Level 3
Level 4
Explanation / Notes
Default