Selecting of the Operating Mode
The function of start- and restart interlock, as well as of the contactor monitoring can be
adjusted on the device.
Upon delivery, the start- and restart interlock are active, the contactor monitoring is
inactive.
Remove the transparent front screen in order to change the settings. The start- and restart
interlock can be switched-off on the left switch (switch 1).
Start- and restart interlock active, contactor monitoring inactive
The function of the contactor monitoring can be switched-off on the right switch (switch 2).
Fig. 5.10-1:
Adjustment of the operating mode (start- and restart interlock active,
contactor monitoring inactive)
Fig. 5.10-2:
Adjustment of the operating mode (start- and restart interlock inactive,
contactor monitoring inactive)