Control of the motor contactors happens via K1 and K2. If a contact of K1 or K2 should
weld, a message is issued to the TMC 66 through the feedback circuit. A new start of the
unit is possible only after removal of the failure in the output circuit.
5.9
Wiring of the Signal Outputs
Two signal outputs are integrated in the TMC 66. Both are HIGH active, positive switching
safety related transistor outputs and can be either directly connected to a PLC or control a
status display of a machine.
The signal output "Safety on" is always active if the safety relay outputs are closed.
Fig. 5.8-3:
Wiring safety output
Fig. 5.9-1:
Wiring of the signal outputs
Signal output "Error"
Signal output "Safety On"