![Leuze electronic SD4R 14 Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/leuze-electronic/sd4r-14/sd4r-14_connecting-and-operating-instructions_1884032022.webp)
Display elements
22
SOLID-4
Leuze electronic
DEUTSCH
E
NGLISH
FRANÇAIS
IT
A
LIANO
ESPAÑOL
N
EDERLANDS
5
Display elements
5.1
SD4T Transmitter status displays
If the transmitter’s green LED1 is lit, this indicates that the supply voltage is present.
Table 5.1-1:
Transmitter, LED status displays
a = LED1 (green/red)
b = LED2 (green/red)
Fig. 5.1-1:
Transmitter status displays
Display
Meaning
LED1
green
LED2
off
Operating voltage present, TC1 selected
LED1
green
LED2
green
Operating voltage present, TC2 selected
LED1
green
LED2
red
Operating voltage present, TC1 or TC2 selected,
external test signal activated
LED1
red
LED2
any
Device fault
a
b