Commissioning and configuration
52
RFM - HF RFID Series
Leuze electronic
7.6
LED indicators
Table 7.4:
LED indicators and their meaning
LED
State
Meaning
PWR
Off
Device OFF
- No supply voltage
READ
Green
continuous light
and
red
continuous light
for approx. 3s
Device OK, initialization phase
- Self test running
ACT
PWR
Yellow,
continuous light
Device ready
ACT
Red,
continuous light
Device (antenna) activated
- Reading gate open/precharged for writing
- Transponder is expected
READ
Green,
flashing
Transponder has been detected
- Data output via interface