Commissioning and configuration
Leuze electronic
RFM - HF RFID Series
39
TNT
35/7-2
4
V
7
Commissioning and configuration
With the Leuze
RF-Config
software program, a Windows-based graphical user interface is
available for configuring the RFID devices of the RFM series. Operating systems: Windows
2000, Windows XP, Windows Vista, Windows 7.
You can download the RF-Config software program from the Leuze website at
–>
Download –> identify –> Stationary RFID read/write systems
.
7.1
Antenna tuning at the installation site
RFM 12 and RFM 32
The RFM 12 and RFM 32 devices are tuned so that the full operating range is ensured when
mounted in the standard manner or in a mounting holder with no metal in the area around
the active surface. The RFM32 can also be mounted directly on metal, though this results
in an approx. 10% reduction of the max. operating range.
RFM 62
With the RFM 62, a check and, if necessary, antenna tuning must always be performed after
mounting. To do this, first connect the device to the voltage supply, open the housing cover
and use the "
environment
" slide switch to set whether the distance of the RFM 62 to metal
surfaces is greater or less than 20mm.
Figure 7.1:
RFM 62 antenna tuning
Antenna tuning
"Initialize Trimming"
button
Environment preselection
(distance to metal)