Leuze electronic
MSI-TB
28
After switching on the safety relay, display elements (LEDs, see chapter 3.2 Display elements ) assist in
checking the proper function and troubleshooting.
In case of failure, you can determine the fault from the LED displays. With the error message you can
determine the cause of the fault and initiate measures to rectifying it.
Switch off the machine and leave it switched off.
Analyze and eliminate the cause of the fault (see chapter 11.2 Operating displays of the LEDs ).
If you are unable to rectify the fault, contact the Leuze electronic branch responsible for you or call the
Leuze electronic Hotline.
EDM
flashing
Fault in the EDM wiring Check the wiring of the
connected contactors.
Sensor
flashing
Fault in the wiring of the
light beam safety
devices
Check the wiring of the
light beam safety
devices.
Sensor, EDM and start
simultaneous flashing
Internal device error
If a restart is unsuccess
-
ful, contact customer
service.