Commissioning and configuration
Leuze electronic
MA 235
i
69
TNT
35/7-2
4
V
12.5
Setting the read parameters on the Leuze device
Commissioning the Leuze device
To commission a read station, you must prepare the Leuze device on the MA 235
i
for its
reading task. Communication with the Leuze device occurs via the service interface.
Notice!
For further information on connecting and using the service interface, see chapter 9 "Con-
figuration".
To do this, connect the Leuze device to the MA 235
i
.
Depending on the Leuze device, this occurs either via a connection cable (accessory no.:
KB 031-1000) or directly on the MA 235
i
. The service connector and corresponding
switches can be accessed with the housing cover open.
Select the "DEV" service switch position.
Connect the service interface; call up the terminal program
Connect your PC to the service connector via the RS 232 cable.
On the PC, call up a terminal program (e.g., BCL-Config) and check whether the interface
(COM 1 or COM 2) to which you have connected the MA 235
i
is set to the following Leuze
standard setting: 9600 baud, 8 data bits, no parity, 1 stop bit and STX, data, CR, LF.
You can download the config. tool from
for BCL, RFID, etc.