Device description
Leuze electronic
MA 235
i
17
TNT
35/7-2
4
V
Service interface
The service interface can be accessed once the MA 235
i
housing cover has been removed
and features a 9-pin Sub-D connector (male). A crossed RS 232 connection cable is required
to make the RxD, TxD and GND connections.
Figure 4.3:
Connecting the service interface to a PC/terminal
Attention!
For the service PC to function, the RS 232 parameters must be the same as those of the
MA. The Leuze standard setting of the interface is 9600bd, 8N1 and STX, data, CR, LF.
4.5
Fieldbus systems
Various product variants of the MA 2xx
i
series are available for connecting to different
fieldbus systems such as PROFIBUS DP, PROFINET-IO, DeviceNet, CANopen and Ethernet
or EtherCAT.
4.5.1
CANopen
General information on CANopen
Figure 4.4:
Bus topology
5 GND
3 TxD
2 RxD
GND 5
TxD 3
RxD 2
1
1
PC/terminal
COM interface
MA 235
i
Service interface
Terminator
Trunk Line
Tap
Terminator
Drop
Line
PLC