Extended configuration – Leuze electronic webConfig tool
Leuze electronic
LSIS 472i
39
Select
CONFIGURATION > PROGRAMS
.
Select the active check program (
Rack Near
or
Rack Far
).
Select
CONFIGURATION > DEVICE > Digital I/Os
.
The
CONFIGURATION OF DIGITAL I/OS
dialog is displayed.
Figure 9.12:
CONFIGURATION OF DIGITAL I/OS
dialog
Set the configuration of the digital switching inputs/outputs according to the requirements of the appli
-
cation.
Table 9.2:
Factory settings of the digital switching inputs/outputs
9.3.11 Assigning digital switching outputs the measurement values
Check-program-specific assignment of tool results to the programmable digital switching outputs.
Select
CONFIGURATION > PROGRAMS
.
Select the active check program (
Rack Near
or
Rack Far
).
Select
CONFIGURATION > PROGRAM > Tools > Output > Digital I/O
.
The
TOOL CONFIGURATION - Digital I/O
dialog is displayed.
IO port
IO mode
Function
IO1
Input
Activation - program start
Reading gate start/stop
IO2
Input
Program selection 1
IO3
Input
Program selection 2
IO4
Input
Error image memory active
Start writing images to ring buffer
IO5 … IO8
Output
Programmable 1 … 4
Outputs for compartment fine positioning