![Leuze electronic LSIS 472i M45-I1 Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/leuze-electronic/lsis-472i-m45-i1/lsis-472i-m45-i1_operating-instructions-manual_1884019032.webp)
Extended configuration – Leuze electronic webConfig tool
Leuze electronic
LSIS 472i
32
9.3.3 Selecting the check program
There is a check program stored on the device for the detection of both the
Rack Near
and
Rack Far
hole
positions.
Select
CONFIGURATION > PROGRAMS
.
The
Overview of Check Programs
dialog is displayed.
Figure 9.3:
Overview of Check Programs
Select the check program that you would like to activate (
Rack Near
or
Rack Far
).
Table 9.1:
Overview of digital inputs for check programs
9.3.4 Configure compartment fine positioning
To commission more quickly, you can set the most important parameters for the check programs (
Rack
Near
and
Rack Far
) via a configuration dialog.
Alternatively, you can make the configuration settings for compartment fine positioning manually; see
NOTICE
Configuration changes only in the
Service
operating mode!
Changes made using the
CONFIGURATION
function can only be performed in the
Service
operating
mode.
Digital input IO2
Digital input IO3
Selection ID
Check program
0
0
0
Rack Near
1
0
1
Rack Far
0
1
2
Not defined
1
1
3
Not defined
The configuration for compartment fine positioning for faster commissioning is only available if
the device is directly connected to the PC/laptop.