Configuration using configuration codes
30
Technical description LSIS 22x
Leuze electronic
7
Configuration using configuration codes
The LSIS 22x is configured with the aid of configuration codes. After reading in these
codes, the device parameters are set in the device and permanently stored.
Notice!
Using Aztec configuration codes, many parameters can be set simultaneously; using
1-dimensional configuration codes, on the other hand, it is generally only possible to set
individual parameters.
7.1
Configuration of interface
7.1.1
RS 232 parameter - LSIS 222 M5M-R1
By reading in the following configuration code, the RS 232 interface is set to the following
standard parameters (factory settings):
• Baud rate
9600bit/s
• Data format
8
data bits,
no
parity,
1
stop bit
• Framing
<STX>
DATA
<CR><LF>
• No read character
’
?
’
• Manual trigger mode
start command:
<SYN>T<CR>
stop command:
<SYN>U<CR>
Figure 7.1:
Configuration code RS 232 standard parameters
Notice!
The LSIS 222 M5M-R1 and the connected host must be set to the same interface parame-
ters.