LESsoft configuration software
76
Technical description LES
Leuze electronic
Activation
Under
Activation
the
Regard
setting has the effect that the laser is switched on and off
according to the level at the activation input or via PROFIBUS. Detailed information on this
topic can be found in chapter 4.2.2.
When the
Disregard
setting has been selected, the laser always remains switched on,
independent from the level at the activation input or the PROFIBUS activation (factory
setting).
Trigger Output Mode
Under
Trigger Output Mode
you can activate the cascading output using
Cascading
.
Detailed information on this topic can be found in chapter 4.2.4. When the
Disable
setting
has been selected, the cascading output will not be set (factory setting).
Light Exposure
Using
Light Exposure
you can control the exposure duration of the laser during measure-
ment value detection and adapt it to the reflective properties of the objects to be detected.
Select an exposure setting that displays a continuous line around the object contour.
Then try to achieve a line on a flat surface that is as continuous as possible.
Field of View
Using
Field of View
you can restrict the measurement range of the LPS. The same
happens if you click on the square handles of the measurement range framed in blue with
the mouse and then pull.
Factory settings for
Field of View
:
By restricting to the necessary detection range, ambient light or undesired reflections can
be suppressed.
Apply Settings
The
Apply Settings
button temporarily transmits the settings for the current inspection
task to the sensor. When switched off, the data/settings are lost.
Notice!
If an inspection task was changed, permanent storage in the sensor should be performed
with
Configuration -> Transmit to Sensor
.
LES 36…