LESsoft configuration software
Leuze electronic
Technical description LES
75
TNT
35/7-2
4
V
9.4.1
Standard tab - Task Parameters panel
Inspection Task Selection
In the
Inspection Task Selection
panel, you can select inspection tasks.
Notice!
By default, changeover of the inspection tasks via the PROFIBUS master (PLC) has priority
over LESsoft. In this field, the selection of the inspection task with LESsoft is only possible
if, under
Global Parameters
there is
no
tick in front of
Enable External Inspection
Task Selection
. Otherwise, the inspection task can only be selected via the process
interface.
By removing the tick in the
Enable External Inspection Task Selection
check
box, the inspection task cannot be changed via the process interface while configuration is
being performed. After configuring with LESsoft and before transmitting the settings to the
sensor ('Transmit to Sensor'), the
Enable External Inspection Task Selection
check box must again be selected. Only then can inspection tasks be selected via the pro-
cess interface.
The upper drop-down menu
Inspection Task Selection
lets you select one of the 16
possible inspection tasks. After the selection of the inspection task, the associated param-
eters are loaded and displayed. You can edit these parameters and save the edited param-
eters under the same name.
In the
Name
field, you can assign a meaningful name (max. 12 characters) to the inspection
task selected above and save it by clicking on
Accept
.
By saving via the button
Apply Settings
,
the currently displayed
inspection task is
temporarily stored in the sensor. When switched off, the data/settings are lost.
By saving via
Configuration -> Transmit to Sensor
menu command
all inspection
tasks created
are transmitted to the sensor, where they are permanently stored.
Notice!
If an inspection task was changed, permanent storage in the sensor should be performed
with
Configuration -> Transmit to Sensor
.
The common procedure for creating and storing inspection tasks is described in chapter
9.6, "Definition of inspection tasks" on page 94 .
Operation Mode
In
Operation Mode
you can configure using
Free Running
that the LES continuously
detects and outputs measurement data (factory setting). With
Input Triggered
the LES
captures measurement data only if a rising edge is present at the trigger input or if one of
the "Ethernet Trigger" (chapter 10.3.4) or PROFIBUS Trigger (chapter 11.5) commands is
being used. Detailed information on this topic can be found in chapter 4.2.3.