Specifications
128
Technical description LES
Leuze electronic
14
Specifications
14.1
General specifications
Optical data
LES 36…
LES 36HI…
Measurement range
1)
in
Z
direction 200 … 800mm
200 … 600mm
Light source
laser
Wavelength
658nm (visible red light)
Max. output power
< 8mW
Pulse duration
3ms
Laser line
600 x 3mm
at 800mm
approx. 170 x 1.5mm
at 600mm
Error limits (relative to measurement distance)
Resolution
2)
3)
in
X
direction
in
Z
direction
1 … 1.7mm
1 … 3mm
0.2 … 0.6mm
0.1 … 0.9mm
Linearity in
Z
-direction
3)
±1%
Repeatability in
Z
-direction
3)
0,5%
B/w detection thresholds
1% (6 ... 90% diffuse reflection)
Object detection
Minimum object size in
x
direction
4)
2 … 3mm
0.6 … 2mm
Minimum object size in
z
direction
2)
2 … 6mm
0.4 … 3mm
Timing
Measurement time
10ms
Delay before start-up
approx. 1.5s
Electrical data
Operating voltage U
B
5)
18 … 30VDC (incl. residual ripple)
Residual ripple
15% of U
B
Open-circuit current
200mA
Ethernet interface
UDP
Switching outputs
1 (ready) / 100mA / push-pull on X1
6)
1 (cascading) / 100mA / push-pull on X1
6)
4 / 100mA / push-pull on X3
6) 7)
(only LES 36/VC6 and LES 36HI/VC6)
Inputs
1 (trigger) on X1
1 (activation) on X1
3 (selection of inspection task) on X3
8)
(LES 36/VC6 and LES 36HI/VC6)
Signal voltage high/low
(U
B
-2V)/
2V
Analog output (LES 36/VC, LES 36HI/VC6)
Analog output
voltage 1 … 10V, R
L
2k
current 4 … 20mA, R
L
500