11.1.3 Online commands for system control
Activate decoding
Command
’+’
Description
The command activates configured decoding.
Parameter
None
Acknowledgment None
Deactivate decoding
Command
’-’
Description
The command deactivates configured decoding.
Parameter
None
Acknowledgment None
11.2
XML-based communication
You can send commands for control and configuration directly to the code reader via XML-based communi-
cation.
• The code reader must be connected to a computer (host) via the Ethernet interface (see chapter 8.3.4
"Ethernet host communication").
• The code reader is designed as an XML server and communicates on port 10004.
You can find detailed information on XML-based communication on the Leuze home page:
www.leuze.com
• Enter the type designation or part number of the device as the search term.
• You can find the information on the
Downloads