PROFINET
Leuze electronic
DCR 248i
81
10.4.20 Module 108 – Entry data 8
PROFINET-IO module identifier
• Module ID: 1108
• Submodule ID: 1
NOTICE
Ä
Data reset does
not
affect the output data toggle bits
Ä
If fragmentation is used, the application must set the output data of the entry data fragmen-
tation module for each fragment that is to be transmitted before the toggle bit is toggled in
the entry data module (see chapter 10.4.4 "Module 16 – Fragmented entry").
Description
The module defines the transfer of entry data to a command interpreter (Cmd interpreter) in the device.
Tab. 10.30:
Input data structure module 108
Input data
Address
Data type
Value range
Default
Unit
Explanation
Data accep-
tance toggle
bit
0.0
Bit
0->1: Data have
been accepted
1->0: Data have
been accepted
0
---
The signal shows that
the device has ac-
cepted the data or the
data fragment.
Data rejec-
tion toggle bit
0.1
Bit
0->1: Data have
NOT been ac-
cepted
1->0: Data have
NOT been ac-
cepted
0
---
The device has re-
jected the acceptance
of the data or the data
fragment.
Reserved
0.2
Bit
0
---
Free
0.3
Bit
0
---
Free
Error code
0.4-0.7
Bit
0: No error
1: Receive buffer
overflow
2: Sequence er-
ror
3: Invalid length
entry
4: Invalid frag-
ment length entry
5: Length change
in a sequence
0
---
Cause of error for re-
jection of the fragment.
Input data length: 1 byte
Tab. 10.31:
Output data structure module 108
Output data
Address
Data type
Value range
Default
Unit
Explanation
Reserved
0.0
0
Free
0.1
0
Free
0.2
0
Free
0.3
0
---
Free
0.4
0
---
Free