Electrical connection
Leuze electronic
DCR 248i
32
7
Electrical connection
CAUTION
Safety notices!
Ä
Before connecting the device, please ensure that the operating voltage matches the value
printed on the nameplate.
Ä
Only allow competent persons to perform the electrical connection.
Ä
Ensure that the functional earth (FE) is connected correctly.
Fault-free operation is only guaranteed if the functional earth is connected properly.
Ä
If faults cannot be rectified, take the device out of operation. Protect the device from acci-
dentally being started.
NOTICE
Shielding connection!
The shielding is connected via the M12 connector housing.
NOTICE
UL applications!
For UL applications, use is only permitted in Class 2 circuits in accordance with the NEC (Na-
tional Electric Code).
NOTICE
Protective Extra Low Voltage (PELV)!
The device is designed in accordance with protection class III for supply with PELV (Protective
Extra-Low Voltage).
NOTICE
Degree of protection IP65!
Degree of protection IP65 is achieved only if the connectors and caps are screwed into place.