Mounting
Leuze electronic
DCR 248i
28
0 x 0
20 x 15
40 x 30
60 x 45
80 x 60
100 x 75
120 x 90
140 x 105
0
50
100
150
200
250
300
350
1
3
4
2
1
Camera distance [mm]
2
Reading field: width x height [mm]
3
N1-optics, M1-optics
4
F-optics
Fig. 6.6:
Relationship between camera distance and reading field size
6.2
Mounting the code reader
NOTICE
Information on mounting the code reader can also be found in document "Quick Start Guide
DCR 200i".
6.2.1
Mounting with M4 fastening screws
Ä
Mount the device on the system with M4 fastening screws (not included in delivery contents).
ð
Max. tightening torque of the fastening screws: 1.4 Nm
ð
Location and thread depth of the mounting thread: see chapter 15.3 "Dimensioned drawings"
6.2.2
Mounting with the BTU 320M-D12 mounting system
Mounting with a BTU 320M-D12 mounting system is intended for 12-mm rod mounting. For ordering infor-
mation, see chapter 16.5 "Other accessories".
Ä
Mount the mounting system on the rod with the clamp profile (system-side).
Ä
Mount the device to the mounting system with M4 fastening screws.
ð
Max. tightening torque of the fastening screws: 1.4 Nm
ð
Location and thread depth of the mounting thread: see chapter 15.3 "Dimensioned drawings"