Functions
Leuze electronic
DCR 248i
19
• Example 2
The code reader is to perform a partial comparison of two characters "42". Beginning with the string
"42", any number of characters and content may follow.
• Comparison string entered in the webConfig tool: ^42
• Positive reference code comparison (match):
42
345
• Negative reference code comparison (mismatch): 12345
NOTICE
Using space characters with regular expressions!
Ä
When entering regular expressions, note the use of space characters.
4.3
Code quality
Overview
To check the code quality, you can activate the
Code quality
function. This function determines the code
quality for bar codes and 2D-codes in compliance with ISO/IEC 15416 and ISO/IEC 15415.
NOTICE
Activating the
Code quality
function increases the decoding time.
The code quality is given as follows: A … F
• A = High quality
• F = Low quality
The following options are available:
• Determination of individual features for bar codes and 2D-codes
• Setting of a minimum quality (= NOMINAL MINIMUM)
• Output of each feature via the interface and as a programmable switching output
ISO/IEC 15416 mode: Individual features for bar codes
• Overall quality
• Symbol contrast (SC)
• Modulation (MOD)
• Decodability
• Minimal edge contrast (EC
min
)
• Minimal reflectance (R
min
)
• Defects
• Decodes
ISO/IEC 15415 mode: Individual features for 2D-codes
• Overall quality
• Symbol contrast (SC)
• Modulation (MOD)
• Decodability
• Fixed pattern damage (FPD)
• Axial non-uniformity (AN)
• Grid non-uniformity (GN)
• Unused error correction (UEC)
• Reflectance margin