Appendix
Leuze electronic
DCR 202i
74
17.3 Configuration via configuration codes
The code reader can also be configured using configuration codes. The device parameters in the device
are set and permanently saved after reading this code.
Configuration changes via the configuration codes are only possible via button activation on the control
panel of the device (
AUTO
function).
Proceed as follows to read in a configuration code:
Connect the code reader to the operating voltage and activate the
AUTO
function on the control panel.
Hold the configuration code at the correct distance in front of the optics of the code reader.
• The code reader adjusts the illumination and reads the configuration code.
• The code reader changes the device configuration and saves the new configuration.
Reset to factory settings (without IP address)
Figure 17.13: Configuration code: reset to factory settings
Setting the IP address to the Leuze default address
Figure 17.14: Configuration code: Setting the IP address
DHCP activation
Figure 17.15: Configuration code: DHCP activation
NOTICE
Read in configuration codes individually!
The configuration codes can only be read in individually.