Starting up the device - Basic configuration
Leuze electronic
DCR 202i
36
8.3
Setting the communication parameters
With the communication parameters, you determine how data is exchanged between device and host
system, monitor PCs etc.
8.3.1 Manually setting the IP address
Set the IP manually if your system does not include a DHCP server or if the IP addresses of the devices
are to be set permanently.
Factory settings for the network address of the code readers of the DCR 200i series:
• IP address: 192.168.060.101
• Subnet mask: 255.255.255.0
Setting the IP address via PC/laptop
Set the network address on the PC (example for Windows7).
Log in as administrator.
Select
Start > System control > Network and Internet > Network and Sharing Center
.
Select
LAN connection
and double-click to open the
Properties
dialog.
Select
Internet Protocol Version 4 (TCP/IPv4)
and click on the [Properties] button.
Set the
IP address
of the PC.
The IP address of the PC must not be identical to the IP address of the code reader.
Example: IP address of the code reader: 192.168.060.101
IP address of the PC: 192.168.060.110
Set the subnet mask of the PC to the same value as on the code reader.
Example: 255.255.255.0
Confirm all of the settings dialogs with [OK] or [Close].
Connect the Ethernet interface of the device directly to the LAN port of the PC.
Start the webConfig tool using your PC's Internet browser with IP address 192.168.060.101.
In the webConfig tool, change the IP address to the IP address of the system:
Configuration > Control > Ethernet DCR
Setting the IP address with Network Scan
Download the program
Network Scan
from the Internet to the PC.
• Call up the Leuze home page: www.leuze.com.
• Enter the type designation or part number of the device as the search term.
• The program
Network Scan
can be found on the product page for the device under the
Downloads
tab.
Connect the Ethernet interface of the device directly to the LAN port of the PC.
Start the program
Network Scan
The program displays all code readers of the DCR 200i series that are available in the network.
Select the DCR 202i code reader from the list.
For information on how to proceed in the event of problems during commissioning of the devices
see chapter 12 "Diagnostics and troubleshooting".
If a problem occurs that cannot be rectified even after checking all electrical connections and set
-
tings on the devices and on the host, contact your responsible Leuze electronic subsidiary or
Leuze electronic customer service (see chapter 13 "Service and support").
NOTICE
The device cannot be accessed if the IP address is incorrect!
Make certain that the correct IP address is entered. The device can otherwise no longer be accessed.