Example configurations
Leuze electronic
CSL 710
66
Map the configured areas 1 and 8 (OR-linked) to the corresponding switching output.
10.2 Example configuration – Teach height area
The following tables show an example configuration for teaching two height areas and the assignment of
two outputs.
• Height area 01 is to be applied to output pin 2 of interface X1.
• Height area 02 is to be applied to output pin 5 of interface X1.
Teach height area 1.
Configure pin 2 as area output.
Map pin 2 to configured height area 1.
Teach height area 2.
Configure pin 5 as area output.
Digital Output 2 Settings
Area mapping 8 … 1
(OR combination)
0b10000000
Digital Output 2 Settings
Area mapping 8 … 1
(OR combination)
0b10000001
A height area is automatically defined using an object.
When teaching a height area, all free beams are combined into one height area.
To define the entire beam area as a height area, a height area is taught without an object.
Description / variables
Configuration of beams in areas
Teach height area
Value: area 1
Active: all beams free
Not active: one beam interrupted
All free beams are configured as area 1.
Description / variables
Configuration of digital inputs/outputs
IO Function
Value: 3 = Area output (area 1 … 8)
The area output signals the logical states of beam
areas 1 … 8.
Description / variables
Configuration of pin 2
Area mapping 8 … 1
(OR combination)
0b00000001
Every area is displayed as a bit.
Description / variables
Configuration of beams in areas
Teach height
Value: area 2
Active: all beams free
Not active: one beam interrupted
All free beams are configured as area 2.