’Online’ commands for the parameter set operations
Copying parameter set
Command
’PC’
Description
This command can only be used to copy parameter sets in their entirety. This can be
used to replicate the three parameter sets
default
,
permanent
and
operating param-
eters
on the basis of one another. In addition, this command can also be used to restore
the factory settings.
Parameter
’PC<Source type><Target type>’
<Source type>
Parameter data set which is to be copied, unit [dimensionless]
'0'
Parameter data set in permanent memory
'2'
Default or factory parameter set
'3'
Operating parameter data set in volatile memory
<Target type>
Parameter set to which the data is to be copied, unit [dimensionless]
'0'
Parameter data set in permanent memory
'3'
Operating parameter data set in volatile memory
Permissible combinations here include:
'03'
Copying the data set from the permanent memory to the operating
parameter data set
'30'
Copying the operating parameter data set to the permanent parame-
ter set memory
'20'
Copying the default parameters to the permanent memory and to the
main memory
Acknowledgment
’PS=<aa>’
<aa>
Status acknowledgement, unit [dimensionless]
’00’
Ok
’01’
Syntax error
’02’
Impermissible command length
’03’
Reserved
’04’
Reserved
’05’
Reserved
’06’
Impermissible combination, source type - target type