Online commands
11.1
Overview of commands and parameters
Online commands can be used to send commands directly to the device for control and
configuration.
For this purpose, the BCL 558
i
must be connected to a host- or service computer via the
interface. The commands described can be sent either via the host or the service interface.
Online commands
With the commands, you can:
• control/decode.
• read/write/copy parameters.
• carry out an automatic configuration.
• teach-in/set reference codes.
• call up error messages.
• call up statistical device information.
• carry out a software reset in order to reinitialize the device.
Syntax
"Online" commands consist of one or two ASCII characters followed by command
parameters.
No separation characters may be entered between the command and the command
parameter(s). Both small and capitalized letters can be used.
Example:
Command
’CA’
: autoConfig function
Parameter
’+’
:
Activation
Transmitted is:
’CA+’
Notation
Commands, command parameters and returned data are enclosed between single quota-
tion marks
’ ’
in the text of this manual.
Most online commands are acknowledged by the BCL 558
i
and any requested data
returned. For commands that are not acknowledged, command execution can be observed
or monitored directly on the device.