Diagnostics and troubleshooting
224
BCL 548
i
Leuze electronic
Table 12.1:
BCL 548
i
alarm and diagnostics messages
BCL 548
i
error category
The BCL 548
i
error category is relevant for prioritizing the alarm or the diagnostics message
but is not transmitted alongside.
Table 12.2:
BCL 548
i
error categories
Laser
The laser operating hour
counter has exceeded the
threshold.
Status
0/0/0
Precaution-
ary mainte-
nance
-
Device-related/precau-
tionary maintenance
Device error
A manufacturer-specific
critical device error has
occurred.
3)
Error
0/0/0
Diagnostics
alarm
Manufac-
turer-specific
Coming only
A continued process
operation of the device is
impossible. This is also
indicated by the activa-
tion of the PWR LED.
Fatal Error
A fatal error has occurred.
This has caused a soft-
ware reset.
Fatal Error
4)
0/0/0
Status
message
-
Device-related
1)
n = module number
2)
Only diagnostics or process alarms actually trigger the transmission of an alarm. All other
types (preventative maintenance and status messages) only lead to an entry into the diag-
nostics buffer and are thus part of the state-based diagnostics.
3)
Collective diagnostic messages for critical device failures.
4)
In the case of a fatal error, the BCL 548
i
carries out a software reset. After the warm start,
the ErrorManager signals the error to the PROFINET application and enters it as status mes-
sage into the diagnostics buffer.
Error category
Alarm type
PWR LED
STATUS/INFO
Status message
Off
WARNING
Status message
Flashes
ERROR
Diagnostics alarm
ON
FATAL ERROR
Diagnostics alarm
ON
1)
1)
The BCL 548
i
carries out a software reset.
Diagnostics
Description
BCL 500
i
category
API/
Slot/
Subslot
Type
Coming/
going
Remark