Online commands
Leuze electronic
BCL 548
i
205
TNT
35/7-2
4
V
11
Online commands
11.1
Overview of commands and parameters
Online commands can be used to send commands directly to the device for control and
configuration.
For this purpose, the BCL 548
i
must be connected to a host- or service computer via the
interface. The commands described can be sent either via the host or the service interface.
Online commands
With the commands, you can:
• control/decode.
• read/write/copy parameters.
• carry out an automatic configuration.
• teach-in/set reference codes.
• call up error messages.
• call up statistical device information.
• carry out a software reset in order to reinitialize the device.
Syntax
"Online" commands consist of one or two ASCII characters followed by command param-
eters.
No separation characters may be entered between the command and the command param-
eter(s). Both small and capitalized letters can be used.
Example:
Command
’CA’
: autoConfig function
Parameter
’+’
:
Activation
Transmitted is:
’CA+’
Notation
Commands, command parameters and returned data are enclosed between single quota-
tion marks
’ ’
in the text of this manual.
Most online commands are acknowledged by the BCL 548
i
and any requested data
returned. For commands that are not acknowledged, command execution can be observed
or monitored directly on the device.