Commissioning and configuration
Leuze electronic
BCL 548
i
189
TNT
35/7-2
4
V
10.13.9 Module 74 – SWIO status and control
PROFINET-IO module identifier
Module-ID 1074
Submodule-ID 1
Description
Module for handling switching input and switching output signals.
Parameter
None
Input data
Input data
Description
Addr.
Data type
Value range
Init value Unit
State 1
Signal state of switching input or out-
put 1
0.0
Bit
0,1
0
-
State 2
Signal state of switching input or out-
put 2
0.1
Bit
0,1
0
-
State 3
Signal state of switching input or out-
put 3
0.2
Bit
0,1
0
-
State 4
Signal state of switching input or out-
put 4
0.3
Bit
0,1
0
-
Comparison state
switching output 1
(Event Counter)
Indicates whether the event counter
has exceeded the set comparative
value.
The bit is reset to the init. value by
resetting the event counter.
1.0
Bit
0: Not exceeded
1: Exceeded
0
-
Switching output 1
Comparison state
toggle bit
(Event Counter)
If "SWOUT switches several times"
was configured as comparison mode,
this bit is toggled each time the event
counter is exceeded.
Indicates whether the event counter
has reached the set comparative
value.
1.1
Bit
0 -> 1: Event counter
exceeded
1 -> 0: Event counter
exceeded
again
0
-
Comparison state
switching output 2
(Event Counter)
Indicates whether the event counter
has exceeded the set comparative
value.
The bit is reset to the init. value by
resetting the event counter.
1.2
Bit
0: Not exceeded
1: Exceeded
0
-
Switching output 2
Comparison state
toggle bit
(Event Counter)
If "SWOUT switches several times"
was configured as comparison mode,
this bit is toggled each time the event
counter is exceeded.
Indicates whether the event counter
has reached the set comparative
value.
1.3
Bit
0 -> 1: Event counter
exceeded
1 -> 0: Event counter
exceeded
again
0
-
Comparison state
switching output 3
(Event Counter)
Indicates whether the event counter
has exceeded the set comparative
value.
The bit is reset to the init. value by
resetting the event counter.
1.4
Bit
0: Not exceeded
1: Exceeded
0
-
Table 10.49: