Commissioning and configuration
170
BCL 548
i
Leuze electronic
10.11.4 Module 55 – String handling parameters
PROFINET-IO module identifier
Module-ID 1055
Submodule-ID 1
Description
This module is used to configure placeholder characters for the bar code segmentation,
filtering, termination, and reference code processing.
Parameter
Parameter length
3 byte
Input data
None
Output data
None
Parameter
Description
Addr
.
Data type
Value range
Default
Unit
Wildcard
character
This parameter is similar to the "don't care
character" parameter. The difference between
this and the "don't care character" is that all
subsequent characters, and not only one char-
acter at a certain position, are disregarded
until a character pattern is found in the string
that follows the wildcard character pattern.
This character has the same behavior as the
wildcard character for the DIR command in the
command line interpreter under Windows.
0
UNSIGNED8
32 … 126
‘*‘
-
Don’t care
character
Placeholder character.
Characters at the position of the placeholder
character are ignored in a comparison. This
permits certain areas to be masked.
1
UNSIGNED8
32 … 126
‘?‘
-
Delete character
Delete character for bar code and identifier fil-
tering (characters at the position of the delete
character are deleted in a comparison. This
permits certain areas to be deleted).
2
UNSIGNED8
32 … 126
‘x‘
-
Table 10.34:
Parameters for module 55